J745_199609 Hydraulic Power Pump Test Procedure

09/01/1996

Scope
Content

This test code describes tests for determining characteristics of hydraulic positive displacement pumps used on construction and industrial machinery as referenced in SAE J 1116. These characteristics are to be recorded on data sheets similar to the ones shown herein. Two sets of data sheets are to be submitted: one at 49 °C (120 °F) and one at 82 °C (180 °F).

This test code establishes conditions for pump tests, outlines a procedure for tests, and establishes a method of presenting pump test data. The procedure covers the following determinations: a) derived capacity; b) delivery characteristics; c) power input; d) power loss; e) overall efficiency; f) pressure compensator response and recovery; and g) flow compensator response and recovery.

Details
DOI
https://doi.org/10.4271/J745_199609
Pages
13
Citation
SAE International Technical Standard, Hydraulic Power Pump Test Procedure, SAE Standard J745_199609, Reaffirmed September 1996, https://doi.org/10.4271/J745_199609.
Additional Details
Publisher
Published
Sep 1, 1996
Product Code
J745_199609
Content Type
Technical Standard
Language
English