J745_198603 Hydraulic Power Pump Test Procedure

03/01/1986

Scope
Content
This test code describes tests for determining characteristics of hydraulic positive displacement pumps used on construction and industrial machinery as referenced in SAE J1116. These characteristics are to be recorded on data sheets similar to the ones shown herein. Two sets of data sheets are to be submitted: one at 49 degrees C (120 degrees F) and one at 82 degrees C (180 degrees F). This test code establishes conditions for pump tests, outlines a procedure for tests, and establishes a method of presenting pump test data. The procedure covers the following determinations: a) derived capacity; b) delivery characteristics; c) power input; d) power loss; e) overall efficiency; f) pressure compensator response and recovery; g) flow compensator response and recovery.
Meta TagsDetails
DOI
https://doi.org/10.4271/J745_198603
Pages
13
Citation
SAE International Recommended Practice, Hydraulic Power Pump Test Procedure, SAE Standard J745_198603, Reaffirmed March 1986, https://doi.org/10.4271/J745_198603.
Additional Details
Publisher
Published
Mar 1, 1986
Product Code
J745_198603
Content Type
Recommended Practice
Language
English