In-Process Hole and Fastener Inspection Using a High-Accuracy Laser Sensor

2020-01-0015

03/10/2020

Event
AeroTech
Authors Abstract
Content
Electroimpact has produced a new in-process inspection system for use on drilling and fastening systems. The system uses a high-accuracy, non-contact, laser system to measure the flushness of installed fasteners. The system is also capable of measuring part normality and providing feedback to the machine for correction. One drawback to many automatic inspection systems is measurement error. Many sources of measurement error exist in a production environment, including drilling chips, lubrication, and fastener head markings. Electroimpact’s latest system can create a visualization of the measured fastener for the operator to interpret. This allows the operator to determine the cause of a failed measurement, thus reducing machine downtime due to false negatives.
Meta TagsDetails
Citation
Luker, Z., and Stansbury, E., "In-Process Hole and Fastener Inspection Using a High-Accuracy Laser Sensor," SAE Technical Paper 2020-01-0015, 2020, .
Additional Details
Publisher
Published
Mar 10, 2020
Product Code
2020-01-0015
Content Type
Technical Paper
Language
English