Effects of Cooled Wall Temperature and HC Concentration on Separation Behavior of PM Deposit Layer in an EGR Cooler

2019-01-2357

12/19/2019

Event
2019 JSAE/SAE Powertrains, Fuels and Lubricants
Authors Abstract
Content
We already found that PM layer deposited on the cooled wall in an EGR cooler was separated from the wall under cold start condition. In this study, effects of cooled wall temperature and hydrocarbon (HC) concentration in exhaust gas on the separation behavior of PM deposit layer in a test EGR cooler were investigated experimentally. As a result, it was found that the PM layers which were deposited with high wall temperature was hard to separate from the wall compared with the layers deposited with low wall temperature during the cold start test. As for the HC concentration in exhaust gas, PM layer deposited in higher HC concentration, which was achieved by addition of diesel fuel to the test exhaust gas, was easily separated during the cold start test.
Meta TagsDetails
Pages
7
Citation
ITOH, Y., MURAYAMA, T., ZAMA, Y., and FURUHATA, T., "Effects of Cooled Wall Temperature and HC Concentration on Separation Behavior of PM Deposit Layer in an EGR Cooler," SAE Technical Paper 2019-01-2357, 2019, .
Additional Details
Publisher
Published
Dec 19, 2019
Product Code
2019-01-2357
Content Type
Technical Paper
Language
English